Connect your Modbus devices to IEC 60870-5-104 (TCP) and IEC 60870-5-101 (Serial) SCADA systems. Professional-grade protocol conversion with real-time monitoring, trending, and web-based configuration.
Industry-standard protocols for power systems and SCADA
TCP/IP based telecontrol protocol for wide-area SCADA systems. Supports spontaneous transmission, general interrogation, and time synchronization.
Serial-based telecontrol protocol for RTU communications. Supports balanced and unbalanced transmission modes.
Poll Modbus TCP devices and convert data to IEC format. Supports all Modbus function codes and data types.
Everything you need for professional protocol conversion
Configure devices, mappings, and settings through an intuitive web interface. No special software required.
Built-in historian with configurable retention. View trends and export data to CSV for analysis.
Efficient .NET 8 runtime with minimal resource usage. Handles thousands of data points with sub-second latency.
Execute IEC commands (single/double/setpoint) to Modbus devices. Full command confirmation support.
Live traffic logs for Modbus, IEC, commands, and connections. Debug issues in real-time.
Export and import device configurations. Deploy the same setup across multiple gateways.
Comprehensive support for monitoring and control
| Type ID | Description |
|---|---|
| M_SP_NA_1 (1) | Single Point Information |
| M_SP_TA_1 (2) | Single Point with Time Tag |
| M_DP_NA_1 (3) | Double Point Information |
| M_DP_TA_1 (4) | Double Point with Time Tag |
| M_ME_NA_1 (9) | Measured Value, Normalized |
| M_ME_NB_1 (11) | Measured Value, Scaled |
| M_ME_NC_1 (13) | Measured Value, Short Float |
| M_IT_NA_1 (15) | Integrated Totals |
| Type ID | Description |
|---|---|
| C_SC_NA_1 (45) | Single Command |
| C_SC_TA_1 (58) | Single Command with Time Tag |
| C_DC_NA_1 (46) | Double Command |
| C_DC_TA_1 (59) | Double Command with Time Tag |
| C_SE_NA_1 (48) | Set-Point, Normalized |
| C_SE_NB_1 (49) | Set-Point, Scaled |
| C_SE_NC_1 (50) | Set-Point, Short Float |
| C_IC_NA_1 (100) | General Interrogation |
One-time payment, no subscription
Where Max IEC Gateway fits in your infrastructure
Connect Modbus-based protection relays and meters to IEC 104 SCADA.
Integrate pumps, valves, and flow meters with central control systems.
Bridge Modbus HVAC and energy systems to enterprise SCADA.
Connect solar inverters and wind turbines to grid control systems.
Download the free trial and start converting protocols in minutes.